What is system fault level?

Fault Level at any given point of the electric power system is the maximum current that would flow in case of short circuit condition.

How do you calculate fault level?

Fault MVA at Motor Control Panel = Base MVA / Z Pu-a. Fault MVA at Motor Control Panel = 2.5 / 0.27317. Fault MVA at Motor Control Panel = 9 MVA. Fault Current = Fault MVA / Base KV.

What reduces fault level in an electrical system?

Reactors can be installed anywhere in the distribution circuit in order to limit the fault current. Since they are essentially a linear inductive reactance, their impedance will add arithmetically to the system impedance and result in a reduction of the fault currents.

What is meant by fault level in high voltage system?

Fault Level means the current expected to flow into a short circuit at a stated point on the System, and which may be expressed in kA or in MVA.

How do you convert kA to MVA?

For a three phase fault, divide total calculated SC MVA value by 1.73 * kVLL to get short circuit current values in kA.

What is the fault level in 11kV?

High voltage fault level limits

Voltage level (kV) Short circuit level (MVA) Short circuit level (kA)
132kV 5,715/7,200 MVA 25/31.5 kA
110kV 4,763/6,000 MVA 25/31.5 kA
33kV 749/1,428 MVA 13.1/25 kA
11kV 250 MVA 13.1 kA

What causes high fault current?

Fault currents are caused by very low impedance short circuits. These may be shorts to ground or across phases. The resulting high current flow can result in overheating of equipment and conductors, excesses forces, and at times even serious arcs, blasts, and explosions.

Why does fault occur in power system?

A fault in a circuit is the disturbance or failure, which interfere the normal system operation. Fault (shown in Fig. 1) usually occurs in a power system due to insulation failure, flashover, physical damage such as wire blowing together in the wind, an animal coming in contact with the wire.

How many MVA are in kVA?

Therefore, it takes 1,000 kilo-volt amperes to get one mega-volt ampere. Divide the number of kVA by 1,000 to convert to MVA. For example, if you have 438 kVA, divide 438 by 1,000 to get 0.438 MVA.

What is base MVA?

Base value is used in power system calculations. Electrical quantities are expressed as a percentage of the base value of that electrical quantity. For example if the base MVA of an electrical system considered is 100MVA, then a 50MVA generator MVA rating is expressed as 0.5p.u (50/100).

What are the two types of fault current?

Electrical faults in three-phase power system mainly classified into two types, namely open and short circuit faults.

Which fault occurs most?

Line to ground fault
Line to ground fault (L-G) is most common fault and 65-70 percent of faults are of this type. It causes the conductor to make contact with earth or ground. 15 to 20 percent of faults are double line to ground and causes the two conductors to make contact with ground.